Markertek - The Future of Broadcast Supply

Call 800-522-2025
M-F 8:30am - 7pm EST

Free Shipping Promo Box

FREE SHIPPING No Minimum Order!

SHOP MARKERTEK EVERYDAY for all of your needs. Free shipping on almost every order placed on our website.
Special order & oversized freight intensive items ship at an additional cost. Continental US orders only.
Ask about our new Economy International Shipping Options.

Secure LoginClose X

Returning Markertek Customers

New Markertek Customers

Why Create an Account?

Creating a Markertek account now will save you time on future orders. You'll have full access to your order history and a personalized shopping experience.

DNF AIB-1 AnyWhere Interface Box GPI Control / Monitoring & Data Conversion Interface
  • DNF AIB-1 AnyWhere Interface Box GPI Control / Monitoring & Data Conversion Interface
  • DNF AIB-1 AnyWhere Interface Box GPI Control / Monitoring & Data Conversion Interface
Questions? Ask a Markertek Expert:
800-522-2025 Email

DNF AIB-1 AnyWhere Interface Box GPI Control / Monitoring & Data Conversion Interface

Manufacturer: DNF Controls

Item #: DNF-AIB-1   •   MFG #: AIB-1


List Price:$1,050.00
Our Price:$984.89

free ship
Availability: Usually ships in 3-10 business days
This item is currently out of stock and will ship the minute we receive it – normally 3-10 business days. Need it sooner? Call 800-522-2025 and we'll make it happen,or email Customer Service for expedited delivery options. Certain Non-Stock Items Valued over $50.00 may Ship FREE UPS GROUND in the Continental US. Multiple quantities of the same non-Stock Item Valued below $50.00 may be ordered to meet the $50 minimum order requirement to qualify for Free UPS Ground Freight. This offer does not apply to certain freight-intensive or hazardous items. Certain restrictions may apply.



    The Missing Link for Control, Monitoring, Interfacing!

    Quickly and easily create control, monitoring, and interface solutions specifically for your project. This One Box Solution requires no adapters, no kludges and delivers "Smart" control where you need it most. Powered over Ethernet (or external power supply) and configured using web browser.

    The AnyWhere Interface Box (AIB) maps an EVENT input to an ACTION output.
    EVENT Inputs- GPI Input, Serial Receive, Ethernet Receive, and Periodic Timer
    ACTION Outputs- GPO Output, Serial Transmit, Ethernet Transmit, and SNMP Transmit
    Any EVENT can trigger any ACTION. One EVENT can trigger one ACTION. One EVENT can
    trigger multiple ACTIONs. GPI events trigger an ON ACTION and an OFF ACTION. Serial
    Receive, Ethernet Receive and Periodic Timer events trigger only ON ACTIONs.

    A GPI ON event triggers an ON ACTION when the GPI turns on. A GPI OFF event triggers an OFF ACTION when it turns OFF. Use the "Do Nothing" action to ignore the GPI ON or OFF event. Use the GPI EVENTS web page to configure the individual operation of the 8 GPIs.

    A Serial Receive and Ethernet Receive event turns ON, when received data matches the assigned, user entered data pattern, and then triggers an ON ACTION. Receive events do not trigger OFF ACTIONs. The Ethernet Receive data must come from the assigned IP address and Port number.

    Serial and Ethernet Receive data pattern matching supports simple and complex pattern matching. Match a single received ASCII (ie: `A') character or match a group of received characters (ie: `control_on`). Match ASCII, binary and hexadecimal characters. Match the whole received character, the first half, the second half, specific bits, or ignore the whole character.

    Control- Monitor- Convert
    GPI > GPO
    GPI >Transmit Serial-RS232, RS422
    GPI >Transmit Ethernet- UDP, TCP/IP, SNMP
    Receive Serial- RS232, RS422 > GPO
    Receive Serial_ RS232, RS422 > Transmit Ethernet­V UDP, TCP/IP, SNMP
    Receive Ethernet- UDP, TCP/IP > GPO
    Receive Ethernet- UDP, TCP/IP > Transmit Serial- RS232, RS422
    Continuous Timer > Transmit Serial- RS232, RS422
    Continuous Timer > Transmit Ethernet- UDP, TCP/IP, SNMP

    • Features

      • Ethernet / Web-browser controlled Relays
      • Web browser control for serial and Ethernet devices
      • Serial to Ethernet / Ethernet to Serial
      • SNMP Trap Notification
      • Watchdog Timer
      • GPI to SNMP Notification
      • Convert Latching to Momentary GPI / Convert Momentary to Latching GPI
      • Ethernet Control / Serial Control / GPI Control
      • Powerful Control Sequencing

      • No software programming or scripting required.
      • Using a web browser, simply select from drop down menus and fill in text boxes.
      • Select an Event Input: GPI Input, Serial Receive, Ethernet Receive, Periodic/ Watchdog Timer ›w Web page button
      • And then assign an Action Output to it: GPO Output, Serial Transmit, Ethernet Transmit, SNMP Transmit, SNMP Trap Notification
      • Use one Event Input to trigger multiple action outputs

      • No Computer Required
      • Your configuration is saved in the AnyWhere Interface Box. Power down and reboot without losing your configuration. Power up without a computer connected.
      • Save the configuration to a PC. Copy it to other AnyWhere Interface Boxes. Restore saved configurations from a PC.

      • Dynamic Transmit Actions
      • Transmit simple or complex ASCII / Hex commands up to 256 characters in length. Transmit SNMP OIDs with Null, Integer or String values. Transmit one command. Wait 1 ­V 999 milliseconds and then transmit a second command. Include multiple commands in one transmit action.

      • Flexible GPI/GPO operation.
      • Isolated inputs and isolated outputs allow different devices to be safely connected together. Convert latching GPI to momentary with defined on time. Convert momentary GPI to latching. Trigger multiple GPOs from one GPI to safely and simultaneously control devices requiring different voltage levels. Use one GPI to alternately toggle two GPOs. Create a radio group of GPOs, allowing only one GPO to be on at a time (break before make).
    • Specifications

      • GPI Inputs: 8- Opto-isolated Inputs
      • Configurable: Wet or Dry
      • GPO Outputs: 8- Isolated Relay contact closures
      • Serial Port Configurable: RS422 Controller or Device; RS232 DTE
      • Ethernet Port: RJ45 10baseT
      • Power: Power over Ethernet or optional external power supply (12W)
      • Size:8.25" W x 4.125" D x 1.5" H


    Continue Shopping View Cart