Tripp Lite OMNISMART350HG 350VA 225W UPS Hospital Medical Tower AVR 120V DB9 RJ11

ITEM #: TRL-OS350HG MFG #: OMNISMART350HG

Primary Image
  • Product Image Thumbnail 1 of 2
  • Product Image Thumbnail 2 of 2
Free Shipping with $49 Minimum Order

List Price:

$808.00

Our Price:

$564.00

Availability: Typically Ships in 3-10 Business Days
iAvailability Description Popup


    OMNISMART350HG - Overview

    Tripp Lite's OMNI SMART 350HG offers medical-grade UPS protection with built-in line interactive voltage regulation, intelligent monitoring and unattended shutdown capability. Hospital-grade plug & outlets, plus built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise equal to 100 microamps. UL 60601-1 listed as medical electrical equipment. 330VA power handling capacity supports computers, inter-networking equipment and other critical loads during commercial power failures. Line interactive voltage regulation corrects brownouts as low as 83V back to normal 120V levels, saving battery reserves for use only during complete power failures. Includes, 2 line phone surge suppression and built-in DB-9 communications port that works with PowerAlert Software and cabling to provide automatic unattended shutdown of connected network and PC applications.

    • Features:

      • Ideal UPS protection for applications in medical patient-care areas where UL 60601-1 listed electrical medical equipment is required
      • Line-interactive voltage regulation corrects brownouts as low as 83V without using battery power
      • Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections
      • Full line isolation prevents shock potential and operational problems in sensitive electronic equipment
      • Resistant to electrostatic discharge
      • Supports loads up to 330VA/225 watts
      • 46 minutes half load runtime (with 165VA load), 18 minutes full load runtime (with 330VA load)
      • 4 protected hospital-grade outlets; 6-ft. cord
      • 1-DB9 serial port for network interface
      • Complete surge protection, line isolation and EMI/RFI noise filtering
      • 2 phone line surge suppression for modems, fax machines and other phone accessories
      • Complete remote monitoring cabling included, PowerAlert UPS management software available via free download
      • 4 diagnostic LEDs indicate AC present, on battery, voltage correction & battery low/replace
      • Battery replacement door and back panel grounding lug
       
    • Specifications:

      • Product Group: UPS SYSTEMS
      • TAA Compliant: No
      • UPS Family: Hospital-Grade
      • UPS Type: Line-Interactive
      • Output Volt Amp Capacity (VA): 330
      • Output Watt Capacity (Watts): 225
      • Nominal Output Voltage(s) Supported: 120V
      • Frequency Compatibility: 60 Hz
      • Output Voltage Regulation (Line Mode): -18%, +8%
      • Output Voltage Regulation (Battery Mode): +/- 5%
      • Output Receptacles: (4) 5-15R
      • Output Receptacle Details: Hospital grade output receptacles
      • Output AC Waveform (AC Mode): Sine wave
      • Output AC Waveform (Battery Mode): PWM sine wave
      • Rated input current (Maximum Load): 2.3A
      • Nominal Input Voltage(s) Supported: 120V AC
      • UPS Input Connection Type: 5-15P-HG
      • Input Circuit Breakers: 3.5A
      • UPS Input Cord Length (ft.): 6
      • UPS Input Cord Length (m): 1.8
      • Recommended Electrical Service: 15A 120V
      • Input Phase: Single-Phase
      • Full Load Runtime (min.): 18 min. (225w)
      • Half Load Runtime (min.): 46 min. (115w)
      • DC System Voltage (VDC): 12
      • Battery Recharge Rate (Included Batteries): Less than 4.5 hours from 10% to 90%
      • Internal UPS Replacement Battery Cartridge: RBC52 (quantity 2)
      • Battery Access: Battery access door
      • Battery Replacement Description: Hot-swappable, user replaceable batteries
      • Voltage Regulation Description: Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89
      • Undervoltage Correction: Input voltages between 89 and 107 are boosted by 14%
      • LED Indicators: 4 LEDs indicate line power, battery power, overload and battery low/replace status
      • Audible Alarm: Audible alarm indicates power-failure and low-battery conditions
      • Alarm Cancel Operation: Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
      • Switches: 2 Switches control off/on power status and alarm-cancel/self-test operation
      • UPS AC Suppression Response Time: Instantaneous
      • UPS Dataline Suppression: 2 line TEL/DSL
      • EMI / RFI AC Noise Suppression: Yes
      • Output Isolation Transformer: Hospital grade load isolation transformer
      • Installation Form Factors Supported with Included Accessories: Tower
      • Installation Form Factors Supported with Optional Accessories: Wallmount (UPSWM - tower mounting kit)
      • Primary Form Factor: Tower
      • UPS Power Module Dimensions (hwd, in.): 10.8 x 5.2 x 7.2
      • UPS Power Module Dimensions (hwd, cm): 27.3 x 13.3 x 18.4
      • UPS Power Module Weight (lbs.): 25
      • UPS Power Module Weight (kg): 11.4
      • UPS Shipping Dimensions (hwd / in.): 14 x 8.5 x 11
      • UPS Shipping Dimensions (hwd / cm): 35.6 x 21.6 x 27.9
      • Shipping Weight (lbs.): 28
      • Shipping Weight (kg): 12.7
      • Cooling Method: NULL
      • UPS Housing Material: PVC
      • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
      • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
      • Relative Humidity: 0 to 95%, non-condensing
      • AC Mode BTU / Hr. (Full Load): 48.8
      • Battery Mode BTU / Hr. (Full Load): 215.8
      • AC Mode Efficiency Rating (100% Load): 0.94
      • Communications Interface: DB9 Serial
      • PowerAlert Software: Free download from www.tripplite.com
      • Communications Cable: DB9 serial cable included
      • Transfer Time: 2-4 milliseconds
      • Low Voltage Transfer to Battery Power (Setpoint): 89
      • High Voltage Transfer to Battery Power (Setpoint): 139
      • Grounding Lug: Grounding lug
      • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
      • High Availability UPS Features: Hot swappable batteries
      • UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI); Tested to UL60601-1 (medical grade)
      • Product Warranty Period (Worldwide): 2-year limited warranty
      • UPS Applications: Hospital/Medical
       
    • Item Includes:

      • OMNI SMART 350HG Hospital Grade UPS System
      • Serial cable for remote monitoring
      • Warranty information
      • Instruction manual
       
    • GTIN:

      0037332098542
       

    OMNISMART350HG - Required Accessories

      California Residents:
      WARNING:
      Cancer and Reproductive Harm - www.P65Warnings.ca.gov