    SU2200XLCD - Overview

    Do you need to protect medium- to large-size servers, networking equipment and telecom systems against data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges? Tripp Lite’s SU2200XLCD SmartOnline Tower UPS System is the solution! Featuring a 2200VA/1800W capacity and true on-line operation with pure sine wave output and zero transfer time to battery, it provides the highest level of power protection for mission-critical equipment. The SU2200XLCD’s large internal battery set supports connected equipment during blackouts, and runtime is expandable with optional external battery packs BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible), sold separately. The SU2200XLCD has 7 AC outlets (6 5-15/20R, 1 L5-20R), including 2 load banks of 3 outlets each that are individually controllable to reboot select equipment on demand or maximize battery runtime for mission-critical equipment. USB and DB9 communication ports support messaging of detailed UPS operational parameters and line power status. Included PowerAlert power management software supports an unlimited number of network UPS systems. The SU2200XLCD also accepts an optional SNMPWEBCARD accessory that enables the UPS to operate as a managed device on the network. It comes backed by a 2-year warranty and $250,000 of Ultimate Lifetime Insurance.

    What does Uninterruptible Power Supply (UPS) mean?
    An uninterruptible power supply (UPS) provides nearly instantaneous power when the main utility power source fails, allowing either time for power to return or for the user to shut down the system or equipment normally by closing running computer system applications and using the operating system to shut down the system. The user has between five and 15 minutes to shut down a system normally or bring an auxiliary power source online to restore the power supply. In addition, most UPS systems also work to address power source electrical surges, sag voltage, voltage spikes, frequency instability, noise interference or harmonic distortion from the ideal sinusoidal wave form. If you're concerned about power failures, especially if you've lost work on your computer due to power outages in the past, you should buy a UPS. A UPS combines a surge suppressor with a big battery, and has special circuitry that detects a power failure and quickly switches over to run your equipment on its battery. The sole purpose of a UPS is to give you a few minutes at the start of a power failure to do two things:
    -Save your work, and
    -Shut down your computer.
    A UPS is not designed to let you continue to use your computer for hours and hours until the power comes back on. If properly chosen, a UPS will give you 5 to 10 minutes (possibly more) to Save and do an orderly Shutdown.

    • Features:

      • 2200VA / 2.2kVA / 1800 watt on-line double-conversion tower UPS
      • 100/110/120/127V 50/60Hz output, 97% efficiency economy mode option
      • Interactive LCD with 10 selectable screens of UPS and site power data
      • Expandable runtime, Hot-swappable batteries
      • USB, RS232 & EPO ports, SNMPWEBCARD option
      • 2 independently switched load banks
      • NEMA 5-20P input; 6 5-15/20R & 1 L5-20R outlets
       
    • Specifications:

      • Nominal Output Voltage(s) Supported: 100V; 110V; 120V; 127V
      • Nominal Voltage Details: 120V default
      • Frequency Compatibility: 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
      • Output Voltage Regulation (Line Mode): +/- 2%
      • Output Voltage Regulation (Economy Line Mode): +/- 10%
      • Output Voltage Regulation (Battery Mode): +/- 3%
      • Output Receptacles: (6) 5-15/20R; (1) L5-20R
      • Load Management Receptacles: Two switchable three-outlet load banks
      • Output AC Waveform (AC Mode): Pure Sine wave
      • Output AC Waveform (Battery Mode): Pure Sine wave
      • Rated input current (Maximum Load): 16A
      • Nominal Input Voltage(s) Supported: 100V AC; 110V AC; 120V AC; 127V AC
      • Nominal Input Voltage Description: 120V factory default
      • UPS Input Connection Type: 5-20P
      • Input Circuit Breakers: 30A
      • UPS Input Cord Length (ft.): 10
      • UPS Input Cord Length (m): 3
      • Recommended Electrical Service: 20A 120V
      • Input Phase: Single-Phase
      • Full Load Runtime (min.): 4.5 min. (1800w)
      • Half Load Runtime (min.): 13 min. (900w)
      • Expandable Battery Runtime: Extended runtime supported via optional external battery packs
      • External Battery Pack Compatibility: BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)
      • Expandable Runtime Description: External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details
      • DC System Voltage (VDC): 48
      • Battery Recharge Rate (Included Batteries): Less than 3 hours from 10% to 90%
      • Internal UPS Replacement Battery Cartridge: RBC48-SUTWR
      • Battery Access: Battery access door
      • Battery Replacement Description: Hot-swappable, user replaceable batteries
      • Voltage Regulation Description: Online, double-conversion power conditioning
      • Overvoltage Correction: 2% output voltage regulation during overvoltages to 150
      • Undervoltage Correction: 2% output voltage regulation during undervoltages to 55V (33% load), 70V (70% load), 100V (100% load)
      • Front Panel LCD Display: Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options
      • Audible Alarm: Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
      • Alarm Cancel Operation: Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
      • Switches: 2 switches control off/on power status and alarm-cancel/self-test operation
      • UPS Housing Material: Steel
      • Green Energy-Saving Features: High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation
       
    • Item Includes:

      • SU2200XLCD SmartOnline Tower UPS System
      • PowerAlert Software CD and Cabling
      • Emergency Power Off (EPO) Cabling
      • Owner’s Manual
       
    • GTIN:

      0037332174659
       