Ward Beck POD33 AES/EBU DARS Generator

ITEM #: WARD-POD33 MFG #: POD33

Primary Image
  • Product Image Thumbnail 1 of 2
  • Product Image Thumbnail 2 of 2

This item is no longer available.
Ask a Markertek Expert if you need assistance finding an appropriate substitute.

(800) 522-2025Email

Items similar to the WARD-POD33

POD33 - Overview

POD33 is a Digital Audio Reference Signal (DARS) generator. This DARS reference signal generator can be synchronized to an external video or AES reference, or it ca be synched to an internally generated 96 kHz or 48 kHz reference. POD33 is designed to selectively provide a 100 Hz, 400 Hz, or 1 kHz tone at amplitudes ranging from Digital Silence through -60 dBFS to 0 dBFS.

POD33 has four independant digital outputs. Each output is available as an unbalanced 75 Ohm or balanced 110 Ohm signal. These outputs can be individually set to be either an AES reference or Word Clock signal. The level and frequency for each individual output can be set.

All controls and read outs are located on the front panel. Input, output and power connections are located on the rear panel. Pluggable 3-pin connectors are provided for the balanced AES signals and unbalanced AES and video reference connections are mand VIA BNC type connectors

  • Features:

    • Digital Audio Reference Signal (DARS) generator
    • can be synchronized to an external video or AES reference
    • can be synched to an internally generated 96 kHz or 48 kHz reference
    • selectively provides a 100 Hz, 400 Hz, or 1 kHz tone
    • amplitudes ranging from Digital Silence through -60 dBFS to 0 dBFS.
    • 4 independant digital outputs
    • each output is available as an unbalanced 75 Ohm or balanced 110 Ohm signal
    • outputs can be individually set to be either an AES reference or Word Clock signal
    • independent level and frequency control for each individual output
    • front panel controls and read outs
    • Digital Audio Reference Signal (DARS) generator
    • can be synchronized to an external video or AES reference
    • can be synched to an internally generated 96 kHz or 48 kHz reference
    • selectively provides a 100 Hz, 400 Hz, or 1 kHz tone
    • amplitudes ranging from Digital Silence through -60 dBFS to 0 dBFS.
    • 4 independant digital outputs
    • each output is available as an unbalanced 75 Ohm or balanced 110 Ohm signal
    • outputs can be individually set to be either an AES reference or Word Clock signal
    • independent level and frequency control for each individual output
    • front panel controls and read outs
     
  • Specifications:

    • AES Reference Input
    • Input Impedance - 75 Ohm AES/EBU 75 Ohm unbalanced
    • Input Impedance - 110 Ohm AES/EBU 110 Ohm transformer balanced
    • Sampling Frequency 32, 44.1, 48, or 96 kHz
    • Level 0.2-7.0 Vp-p
    • Video Reference Input
    • Input Impedance 75 Ohm unbalanced BNC
    • Sampling Frequency NTSC or PAL
    • Level 1.0 Vp-p

      AES Output
    • Resolution 24 Bits
    • Output Standard - 75 Ohm AES/EBU 75 Ohm unbalanced
    • Output Standard - 110 Ohm AES/EBU 110 Ohm transformer balanced
    • Sampling Frequency 32, 44.1, 48, or 96 kHz
    • Jitter Less thank 5 ns
    • Level - 75 Ohm 1 Vp-p 75 Ohm terminated
    • Level - 110 Ohm 3.0 Vp-p 110 Ohm terminated

      Word Clock
    • Output Standard - 75 Ohm AES/EBU 75 Ohm unbalanced
    • Output Standard - 110 Ohm AES/EBU 110 Ohm transformer balanced
    • Sampling Frequency 32, 44.1, 48 or 96 kHz
    • Level - 75 Ohm 1 Vp-p 75 Ohm terminated
    • Level - 110 Ohm 3.0 Vp-p 110 Ohm terminated
     
  • Item Includes:

    • All PODS are supplied in a stand alone desktop POD-PACKAGE, manual and AC power cord. PODS in rack mount assemblies may be ordered as a factory option.
     

POD33 - Required Accessories

    California Residents:
    WARNING: