Tripp Lite SU12000RT4U 12000VA 8400W UPS Smart Online Rackmount 12kVA PDU 208/240/120V

ITEM #: TRL-SU12000RT4U MFG #: SU12000RT4U

Primary Image
  • Product Image Thumbnail 1 of 4
  • Product Image Thumbnail 2 of 4
  • Product Image Thumbnail 3 of 4
  • Product Image Thumbnail 4 of 4

This item is no longer available.
Ask a Markertek Expert if you need assistance finding an appropriate substitute.

(800) 522-2025Email

Items similar to the TRL-SU12000RT4U

SU12000RT4U - Overview

Tripp Lite 12kVA SmartOnline Hot-Swappable Modular Rack/Tower UPS offers 12,000 VA on-line, double-conversion UPS support for server, network and telecommunications equipment. Maintains battery-derived AC output during blackouts with active, full-time power conditioning. Fault-tolerant auto-bypass prevents unexpected service interruptions during overload or internal fault conditions. 4U power module and 4U external battery pack installs in 8 rack spaces (8U). Upright tower installation supported with optional accessories. Maintains full-time sine wave output within 3% of selectable 208/120 or 240/120V AC. Corrects brownouts and overvoltages from 65V to 140V (L-N). Expandable runtime with optional external battery packs. Converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs. Network-grade AC surge and noise suppression. Network management interfaces include combination DB9 RS-232 enabled and dry contact serial port, enhanced USB port and SNMPWEBCARD slot. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Supports Emergency Power Off (EPO) via built-in interface. Front panel LEDs and LCD readout with scroll controls support visual monitoring of all major UPS functions. LED/LCD display panel easily rotates for viewing in rackmount or tower configurations. Split phase 4 conductor hardwire input and output supported. UPS supported outlets include two L6-30R, six C19 and 5 low voltage 5-15/20R. Output connections are mounted on a detachable backplate with manual bypass switch to enable hot-swappable UPS replacement without powering off connected equipment. External battery packs are field replaceable and hot swappable. Attractive all-black color scheme. $250,000 Ultimate Lifetime Insurance.

  • Features:

    • True online, double-conversion UPS provides pure, full-time sine wave AC output free of surges, voltage fluctuations and line noise
    • 12,000 VA / 8400 watt output power capacity with dual voltage output of 208/120 or 240/120V
    • 4U high power density power module and 4U external battery pack supports rackmount installation in 8 rack spaces
    • Dual conversion UPS actively converts raw input from AC to DC, then back to perfect sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
    • Hardwire input terminals and output receptacles are mounted on a detachable back plate with manual bypass switch to enable hot-swappable UPS replacement without powering off connected equipment
    • Provides perfectly regulated, sine wave output power free of line noise, transient surges and frequency variation for the most efficient operation of critical servers, networking and telecommunications equipment
    • Maintains output within 3% of selected 208/120 or 240/120V nominal voltage during brownouts and overvoltages
    • Supports connected equipment during blackouts for 20/7 minutes at half/full load levels, runtime is further expandable with optional external BP192V18-4U battery packs
    • Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
    • Network interfaces support simultaneous communications via DB9 port, USB port and SNMPWEBCARD slot. DB9 port supports RS-232 and dry contact messaging. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X.
    • Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP
    • Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter shutoff, activate self-test and output power control
    • Built-in Emergency Power Off (EPO) interface with cable
    • Includes 13 output receptacles (2 L6-30R, 6 C19, 5 NEMA 5-15/20R) plus hardwire output, all of which are available for simultaneous use
    • Split phase, 4 conductor hardwire input connection (featured on included detachable PDU).
    • Front panel LEDs and LCD readout with scroll button enables visual confirmation of all major UPS functions and current site electrical conditions
    • Front panel switches enable power on/off control, self-test and alarm cancel functions
    • Included adjustable mounting rails support installation in 4 post 19 inch rack enclosures
    • Optional 2-9USTAND set of tower stands supports upright tower installation
    • Optional 2POSTRMKITHD enables installation in 2 post racks (2 required)
    • Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
    • $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)
     
  • Specifications:

    • Rated input current (Maximum Load): 50A
    • UPS Input Connection Type: Hardwire
    • UPS Input Connection Description: 4 wire split-phase input (L1, L2, N, G)
    • Recommended Electrical Service: 50A 208/240-120 Split Phase
    • Input Phase: Single-Phase
    • Full Load Runtime (min.): 7 min. (8400w)
    • Half Load Runtime (min.): 20 min. (4200w)
    • Battery Recharge Rate (Included Batteries): Less than 6 hours from 10% to 80% (typical, full load discharge)
    • Battery Replacement Description: Hot-swappable, user replaceable batteries
    • Voltage Regulation Description: Online, double-conversion power conditioning
    • Overvoltage Correction: 3% output voltage regulation during overvoltages to 140 (measured L1-N : L2-N)
    • Undervoltage Correction: 3% output voltage regulation during undervoltages to 65 (measured L1-N : L2-N)
    • Included Mounting Accessory Description: 2 sets of adjustable 4 post rack rails included
    • Relative Humidity: 0 to 95%, non-condensing
    • AC Mode BTU / Hr. (Full Load): 4286
    • Battery Mode BTU / Hr. (Full Load): 3187
    • AC Mode Efficiency Rating (100% Load): 0.87
    • AC Economy Mode Efficiency Rating (100% Load): 0.94
    • Operating Elevation (ft.): 0-3000m (0 to 10,000 ft.)
    • Audible Noise: 60 dBA at front side 1 meter
    • Operating Elevation (m): 0-3000 m
    • Communications Interface: USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
    • Network Monitoring Port Description: RS232 and contact closure communications are supported on one DB9 port
    • PowerAlert Software: Included
     
  • Item Includes:

    • SU12000RT4UPM 4u UPS Power Module
    • BP192V18-4U External battery pack
    • SUPDMB16K Detachable PDU with manual bypass switch
    • 4 post rackmount installation brackets
     
  • GTIN:

    0037332154897
     

SU12000RT4U - Required Accessories

    California Residents:
    WARNING:
    Cancer and Reproductive Harm - www.P65Warnings.ca.gov