SU16KRT - Overview

Tripp Lite SU16KRT 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 12U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.

  • Features:

    • Tripp Lite SU16KRT 16kVA, 16,000VA / 14,400 watt on-line, double-conversion UPS system in 12U total rack/tower configuration
    • Unique configuration offers 16kVA non-redundant operation and automatic N+1 redundancy at load levels of 8kVA and under
    • Included Parallel PDU with manual bypass switch enables hot-swap replacement of power modules at any supported load level
    • Hardwire input; 2 L6-30R and 8 C19 outlets
    • Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal
    • Supports 50/60Hz operation for worldwide frequency compatibility
    • Expandable runtime with optional external battery packs
    • Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
    • Battery independent restart
    • Highly efficient economy mode option
    • Optional SNMPWEBCARD, RELAYIOCARD and RELAYIOMINI interface modules available (RELAYIOMINI requires removal of USB interface module)
    • Applications utilizing the optional network communications card require two SNMPWEBCARD accessories (install one per included power module)
    • HID-compliant USB interface
    • Includes Free PowerAlert monitoring software; PowerAlert LOCAL, PowerAlert NSA and PowerAlert NMS for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices
    • Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (4 required)
    • Optional 2-9USTAND supports upright tower placement (2 required)
    • Supports Emergency Power Off (EPO) via built-in interface
    • Front panel LEDs and LCD readout with scroll controls
    • LED / LCD display panel rotates for viewing in rackmount or tower configurations
    • External battery packs are field replaceable and hot swappable
    • Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
     
  • Specifications:

    • Output Volt Amp Capacity (VA): 16000
    • Output kVA Capacity (kVA): 16
    • Output Watt Capacity (Watts): 14400
    • Output kW Capacity (kW): 14.4
    • Power Factor: 0.9
    • Nominal Output Voltage(s) Supported: 200V; 208V; 240V
    • Nominal Voltage Details: Voltage selection via front panel LCD interface
    • Frequency Compatibility: 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
    • Frequency Compatibility Details: Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
    • Output Voltage Regulation (Line Mode): +/- 2%
    • Output Voltage Regulation (Economy Line Mode): +/- 10%
    • Output Voltage Regulation (Battery Mode): +/- 2%
    • Output Receptacles: (2) L6-30R; (8) C19
    • Output Circuit Breakers: Two built-in 30A breakers protect one L6-30R outlet each; Eight built-in 20A breakers protect one C19 outlet each
    • Output AC Waveform (AC Mode): Sine wave
    • Output AC Waveform (Battery Mode): Pure Sine wave
    • Rated input current (Maximum Load): 92A (200V), 88.4A (208V), 83.6A (220V), 80A (230V), 76.6A (240V)
    • Nominal Input Voltage(s) Supported: 200V AC; 208V AC; 240V AC
    • UPS Input Connection Type: Hardwire
    • UPS Input Connection Description: 3 wire single phase input (L1, L2, G)
    • Recommended Electrical Service: 100A @ 200V-240V (L, N, PE), or 100A @ 200V, 208V, or 240V (L1, L2, G)
    • Input Phase: Single-Phase
    • Full Load Runtime (min.): 5.5 minutes (14,400 watts)
    • Half Load Runtime (min.): 13.5 minutes (7200 watts)
    • Expandable Battery Runtime: Runtime is expandable with external battery packs
    • External Battery Pack Compatibility: BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH; BP240V1407C-1PH
    • Expandable Runtime Description: For best results, add external batteries in multiples of two so that both included 8kVA power modules have an equal number and type of connected battery packs
    • DC System Voltage (VDC): 240
    • Battery Recharge Rate (Included Batteries): Less than 8 hours from 10% to 90% (typical, full load discharge)
    • Internal UPS Replacement Battery Cartridge: NULL
    • Battery Access: NULL
    • Battery Replacement Description: Hot-swappable, user replaceable external battery packs
    • Voltage Regulation Description: 2% output voltage regulation in standard online, double-conversion mode
    • Overvoltage Correction: Corrects overvoltages up to 300V
    • Undervoltage Correction: Corrects undervoltages as low as 100V
    • LED Indicators: 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
    • Audible Alarm: Unique audible alarms for all major UPS, environmental and power conditions (see manual)
    • Alarm Cancel Operation: Alarm cancel switch
    • UPS AC Suppression Response Time: Instantaneous
     
  • Item Includes:

    • Two SU8000RT3UPM UPS power modules
    • Two BP240V10RT3U battery packs
    • SUPDMB20K parallel PDU with Bypass switch
    • 4 post rackmount installation rails
    • PowerAlert software and cabling
     
  • GTIN:

    0037332158222
     

SU16KRT - Required Accessories

    California Residents:
    WARNING:
    Cancer and Reproductive Harm - www.P65Warnings.ca.gov