Tripp Lite SU6000RT4UTFTAA 6000VA 5400W UPS Smart Online 120/208/240V Rackmount 6URM TAA

ITEM #: SU6000RT4UTFTAA MFG #: SU6000RT4UTFTAA

Primary Image
  • Product Image Thumbnail 1 of 2
  • Product Image Thumbnail 2 of 2

This item is no longer available.

Ask a Markertek Expert if you need assistance finding an appropriate substitute.

(800) 522-2025Email

Items similar to the SU6000RT4UTFTAA

SU6000RT4UTFTAA - Overview

Protects Mission-Critical Rack-Mounted Equipment against Damage, Downtime and Data Loss
This TAA-compliant UPS system protects connected equipment against damage, downtime and data loss due to power outages, voltage fluctuations and transient surges. Featuring a 5400W capacity, high 0.9 power factor, true on-line operation with pure sine wave output and zero transfer time to battery, the Tripp Lite SmartOnline® SU6000RT4UTFTAA provides the highest level of battery backup and AC power protection for critical server, network and telecom equipment. Using the 2U transformer, this 6kVA UPS system can support both low- and high-voltage equipment.

Reliable, Expandable Battery Backup
UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The internal battery set provides 8.5 minutes of support at half load and two minutes at full load. During normal operation, incoming utility power keeps the battery fully charged so backup power will be available when needed. For mission-critical applications demanding continuous uptime, the 6kVA UPS can provide expandable runtime with optional external battery packs, such as Tripp Lite’s field-replaceable, hot-swappable BP192V12RT3UTAA (sold separately). A battery-independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteries.

Easily Hot-Swappable with No Expensive Service Calls or Downtime Needed
With its detachable PDU, the SU6000RT4UTFTAA is easily hot-swappable by a user of any skill set. In bypass mode, the PDU passes power to equipment without the use of the power and battery modules, allowing them to be removed while keeping your application in operation. When making repairs or replacing a battery, no lengthy service calls or downtime are necessary.

  • Features:

    • Zero transfer time between AC power and battery for uninterrupted operation
    • PDU keeps essential equipment powered during hot-swap battery replacement or repair
    • 2U transformer supports power protection of both low- and high-voltage components
    • Optional external batteries provide additional runtime for essential applications
    • Complies with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
     
  • Specifications:

    • Output
    • Output Volt Amp Capacity (VA): 6000
    • Output kVA Capacity (kVA): 6.00
    • Output Watt Capacity (Watts): 5400
    • Output kW Capacity (kW): 5.40
    • Power Factor: 0.9
    • Crest Factor: 3:1
    • Nominal Output Voltage(s) Supported: 120V; 208V; 240V
    • Frequency Compatibility: 60 Hz
    • Frequency Compatibility Details: Output frequency regulation +/-0.05Hz (free running)
    • Output Voltage Regulation (Line Mode): +/- 2%
    • Output Voltage Regulation (Economy Line Mode): +/- 10%
    • Output Voltage Regulation (Battery Mode): +/- 2%
    • Output Receptacles: (4) 5-15R; (8) 5-15/20R; (2) L6-20R; (2) L6-30R
    • Output AC Waveform (AC Mode): Pure Sine wave
    • Output AC Waveform (Battery Mode): Pure Sine wave

      Input
    • Rated input current (Maximum Load): 31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V)
    • Nominal Input Voltage(s) Supported: 208V AC; 240V AC
    • Nominal Input Voltage Description: Factory configured to 208V
    • UPS Input Connection Type: L6-30P
    • UPS Input Cord Length (ft.): 10
    • Recommended Electrical Service: 30A
    • Input Phase: Single-Phase

      Battery
    • Full Load Runtime (min.): 2 min. (5400 watts)
    • Half Load Runtime (min.): 8.5 min. (2700 watts)
    • DC System Voltage (VDC): 192
    • Battery Recharge Rate (Included Batteries): 6 hours from 10% to 90% (typical, full load discharge)
    • Internal UPS Replacement Battery Cartridge: RBC5-192

      Voltage Regulation
    • Voltage Regulation Description: Online, double-conversion power conditioning
    • Overvoltage Correction: Corrects overvoltages as high as 300V (<90% load) and 280V (full load)
    • Undervoltage Correction: Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly

      Surge / Noise Suppression
    • UPS AC Suppression Joule Rating: 2595
    • UPS AC Suppression Response Time: Instantaneous

      Physical
    • Primary Form Factor: Rackmount
    • UPS Power Module Dimensions (hwd, in.): 6.85 x 17.50 x 20.70
    • Rack Height: 6U
    • Maximum Device Depth (in.): 22
    • UPS Power Module Weight (lbs.): 116
    • UPS Power Module Weight (kg): 52.62
    • Stepdown Transformer Dimensions (hwd / in.): 3.50 x 17.50 x 22.00
    • Stepdown Transformer Weight (lbs.): 73
    • Shipping Dimensions (hwd / in.): 22.20 x 23.60 x 29.10
    • Shipping Weight (lbs.): 234.40
    • Cooling Method: Fans
    • UPS Housing Material: Steel

      Environmental
    • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
    • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
    • Relative Humidity: Up to 95%, non-condensing
    • AC Mode BTU / Hr. (Full Load): 1767
    • AC Economy Mode BTU / Hr. (Full Load): 768
    • Battery Mode BTU / Hr. (Full Load): 2279
    • AC Mode Efficiency Rating (100% Load): 90%
    • AC Economy Mode Efficiency Rating (100% Load): 96%
    • Operating Elevation (ft.): 0-3000m (0 to 10,000 ft.)
    • Audible Noise: 60 dBA at front side 1 meter
    • Operating Elevation (m): 0-3000 m

      Line / Battery Transfer
    • Transfer Time: No transfer time (0 ms.) in online, double-conversion mode
    • Transfer Time (Economy Mode): 8ms. typical power failure response in optional economy mode
    • Low Voltage Transfer to Battery Power (Setpoint): 156V (full load) / 100V (50% load or less, derates linearly)
    • High Voltage Transfer to Battery Power (Setpoint): 280V (full load) / 300V (90% load or less)

      Certifications
    • UPS Certifications: Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances); TAA Compliant; Tested to CSA (Canada); Tested to UL1778 (USA)
    • UPS Certification Details: IEC 61000-4-5 1995 B Surge Immunity
     
  • Item Includes:

    • SU6000RTHVPMTAA hot-swappable UPS power module
    • SUPDMB6KTAA detachable PDU w/maintenance bypass switch
    • SU6000XFMR2UTAA low-voltage transformer
    • USB cable
    • DB9 cable
    • EPO cable
    • Rack-mounting hardware
    • Owner's manual
     
  • Warranty:

    • 2-year
     
  • GTIN:

    0037332153920
     

SU6000RT4UTFTAA - Required Accessories

    California Residents:
    WARNING:
    Cancer and Reproductive Harm - www.P65Warnings.ca.gov