Tripp Lite PDU330AT6L2130 PDU 3-Phase Monitored/ATS 208V 8.6kW 2 L21-30P - 6 Foot Cords - 1U

ITEM #: PDU330AT6L2130 MFG #: PDU330AT6L2130

Primary Image
  • Product Image Thumbnail 1 of 5
  • Product Image Thumbnail 2 of 5
  • Product Image Thumbnail 3 of 5
  • Product Image Thumbnail 4 of 5
  • Product Image Thumbnail 5 of 5

This item is no longer available.

Ask a Markertek Expert if you need assistance finding an appropriate substitute.

(800) 522-2025Email

Items similar to the PDU330AT6L2130

PDU330AT6L2130 - Overview

Tripp Lite's PDU330AT6L2130 8.6kW 3-Phase 208V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Working in tandem with a required 0U vertical outlet accessory (sold separately; choose from PDU3V20D354, PDU3V20D354A or PDU3V20D354B), the 1U PDU330AT6L2130 is ideal for data centers and server rooms. Tripp Lite's breakthrough 3-phase rack ATS (U.S. Patent 9,467,006) provides rapid coordination of unsynchronized phases without dropping loads and operates with the high efficiency and reliability required for data center applications.

Dual 6-foot input cords with L21-30P plugs connect to separate primary and secondary 3-phase power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1-6 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.

Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). Tiered access privileges allow both an administrator and a guest to log in. Automated alerts help prevent accidental overloads, power loss and downtime. Digital LED display indicates power availability, voltage, source A/B input status, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module (sold separately).

Note: Requires 0U vertical outlet strip accessory (sold separately).
PDU3V20D354 (54 C13 outlets)
PDU3V20D354A (42 C13 and 12 C19 outlets)
PDU3V20D354B (48 C13 and 6 C19 outlets)

  • Features:

    • Requires Tripp Lite 0U outlet accessory (sold separately)
    • 3-phase L21-30P input and single-phase 208V output
    • Automatic transfer switching within 1-6 ms
    • Ethernet network interface for remote access
    • Digital LED display for real-time status monitoring
    • Patented ATS technology
     
  • Specifications:

    • Output
    • Output Capacity Details: 8.6kW (208V) total capacity; 13.9A max per output phase (L1-L2, L2-L3, L3-L1), 12A max per C13 outlet
    • Frequency Compatibility: 50 / 60 Hz
    • Output Receptacles: C13; C19
    • Output Receptacle Details: 0U vertical output power distribution component is a required accessory; Order REQUIRED PDU accessory PDU3V20D354 (54 C13 outlets), PDU3V20D354A (42 C13 and 12 C19 outlets) or PDU3V20D354B (48 C13 and 6 C19 outlets)
    • Output Nominal Voltage: 208
    • Overload Protection: 3 20A double-pole breakers (1 per breakered outlet bank)

      Input
    • PDU Input Voltage: 208
    • Maximum Input Amps: 24
    • PDU Plug Type: (2) NEMA L21-30P
    • Input Cord Details: Set of 2 inputs enable connection to separate PRIMARY and SECONDARY power sources
    • Input Cord Length (ft.): 6
    • Input Phase: 3-Phase

      User Interface, ALerts & Controls
    • Reported Load Segments: Supports local display of A & B line INPUT CURRENT, INPUT VOLTAGE & FREQUENCY per phase, OUTPUT CURRENT, KW, VOLTAGE & POWER FACTOR per phase, TOTAL OUTPUT POWER (kW), PHASE IMBALANCE (%), TEMPERATURE (C/F), FAULT CODE and SCROLL IP
    • Front Panel LCD Display: Large 3-character display reports data for reported values; Additional 2 character identifies the measurement value or specific location the displayed measurement applies
    • Front Panel LEDs: Set of 6 LEDs indicate A/B input PREFERRED, AVAILABLE & IN USE status; Set of 5 LEDs label the measurement value displayed (AMPS, KW, VOLTS, HZ & POWER-FACTOR); One additional red LED reports BREAKER TRIP status
    • Switches: MODE and ENTER buttons enable navigation and viewing of all reported information
    • Current Measurement Accuracy (Amps): +/-1%
    • Voltage Measurement Accuracy (Volts): +/-1%
    • Power Measurement Accuracy (Watts): +/-1%

      Physical
    • Shipping Dimensions (hwd / in.): 5.00 x 27.95 x 41.54
    • Shipping Weight (lbs.): 42.55
    • Unit Dimensions (hwd / in.): 1.72 x 16.9 x 26
    • Unit Weight (lbs.): 26.8
    • Material of Construction: Steel
    • Form Factors Supported: 1U rackmount ATS module; Separate purchase 0u vertical mount PDU outlet distribution bar sold separate (3 options available)
    • PDU Form Factor: Horizontal (1U)

      Environmental
    • Storage Temperature Range: 5 to 122F (-15 to 50C)
    • Relative Humidity: Up to 95% (non-condensing)
    • Operating Elevation (ft.): 0-10,000
    • Operating Elevation (m): 0-3000

      Special Features
    • Grounding Lug: Included

      Certfications
    • Certifications: Tested to UL/CSA 60950-1 (USA, Canada), FCC Class A (Emissions), RoHS Complaint
     
  • Item Includes:

    • PDU330AT6L2130 8.6kW 3-Phase 208V ATS/Monitored PDU
    • Rack installation brackets
    • Configuration cable
    • Owner's manual
     
  • Warranty:

    • 2-year
     
  • GTIN:

    0037332191519
     

PDU330AT6L2130 - Required Accessories

    California Residents:
    WARNING:
    Cancer and Reproductive Harm - www.P65Warnings.ca.gov