Tripp Lite PDU3EVNR6G60A PDU 3-Phase Monitored 12 C19 6 C13 208/240V 60A 16.2kW - Blue - 0U

ITEM #: TRL-PDU3EVNR6G60 MFG #: PDU3EVNR6G60A

Primary Image
  • Product Image Thumbnail 1 of 5
  • Product Image Thumbnail 2 of 5
  • Product Image Thumbnail 3 of 5
  • Product Image Thumbnail 4 of 5
  • Product Image Thumbnail 5 of 5
Free Shipping with $49 Minimum Order

List Price:

$2,579.62

Our Price:

$1,668.00

Availability: Typically Ships in 3-10 Business Days
iAvailability Description Popup
  • Shipment of this item is subject to a separate oversized-package carrier surcharge.


PDU3EVNR6G60A - Overview

16.2kW 3-Phase PDU Distributes and Monitors Network-Grade Power
This monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for your data center, computer room or high-density network closet, the Tripp Lite PDU3EVNR6G60A features 12 C19 and six C13 208/240V outlets in three breakered load banks, which distribute AC power to rack equipment. Plug-lock insert sleeves are included to prevent equipment cables from becoming accidentally dislodged.

Monitored Per-Outlet PDU Lets You Keep Track of Power Consumption in Real Time
Not only can you remotely monitor voltage and frequency, but the PDU3EVNR6G60A also allows metering of per-phase input current, as well as output current per bank and per outlet. Banks can be individually monitored to ensure proper load balance and prevent downtime. Monitoring each outlet allows you to study power consumption trends for each connected device. This helps you detect hardware problems and network traffic bottlenecks, as well as compare power usage among various devices.

Built-In LX Platform Network Management Card Allows Remote Access 24/7
The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, Telnet or SSH. Full 10/100/1000 Mbps auto-sensing enables optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, FTP, DHCP and NTP.

Color Touchscreen LCD Gives You Important Data at a Glance
An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank and per outlet with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the PDU via PowerAlert® Device Manager. If an EnviroSense2 module is connected, the LCD also displays status and environmental data, including temperature and humidity.

Typical Applications:
Power mission-critical rack equipment in a data center, computer room or high-density network closet in a government, commercial or industrial facility
Monitor power loads from various computers, switches, servers and other networking equipment
Study power consumption trends over time for equipment connected to each individual outlet

  • Features:

    • Advanced remote capabilities include outlet-level current monitoring in real time
    • 12 C19 and 6 C13 208/240V outlets distribute AC power to connected equipment
    • Built-in Java-free HTML5-based LX Platform interface allows you 24/7 remote access
    • Color touchscreen LCD provides current levels, environmental data and network info
    • Installs in 0U of rack space in standard 19 in. racks using included mounting hardware
    • 2-year limited warranty
     
  • Specifications:

    • Input
    • PDU Input Voltage: 208
    • Recommended Electrical Service: 60A 208V Dedicated Circuit with IEC 309 60A Blue compatible outlet
    • Maximum Input Amps: 45
    • PDU Plug Type: (1) IEC-309 60A BLUE (3P+E)
    • Input Phase: 3-Phase
    • Input Cord Length (ft.): 6

      Output
    • Output Capacity Details: 16.2kW (208V) total capacity; 26A max per output phase (L1-L2, L2-L3, L3-L1); 20A max per breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet
    • Frequency Compatibility: 50 / 60 Hz
    • Output Receptacles: (6) C13; (12) C19
    • Output Nominal Voltage: 208
    • Overload Protection: 6 20A circuit breakers, one per output load bank

      User Interface, Alerts & Controls
    • Reported Load Segments: Reports input current per phase (L1, L2, L3) and output current for each breakered load bank (26A combined max per banks B1+B4, B2+B5, B3+B6); 20A Max per banks B1-B6); Outlets are color-coded and labeled for phase and load bank identification; L1-L2 feeds black outlets (B1 & B4); L2-L3 feeds dark-gray outlets (B2 & B5); L3-L1 feeds light-gray outlets (B3 & B6)
    • Front Panel LCD Display: Touchscreen LCD reports NETWORK DATA (IP address, Subnet Mask, Gateway, MAC Address, Device Name, Model, Serial Number)
    • Switches: LX Platform Interface: Recessed reset switch for interface reboot and factory reset
    • Current Measurement Accuracy (Amps): +/-1%
    • Voltage Measurement Accuracy (Volts): +/-1%
    • Power Measurement Accuracy (Watts): +/-1%

      Physical
    • Form Factors Supported: Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-mount compatible racks
    • Material of Construction: Sheet metal
    • PDU Form Factor: Vertical (0U)
    • Shipping Dimensions (hwd / in.): 6.89 x 9.65 x 75.87
    • Unit Dimensions (hwd / in.): 70 x 2.17 x 2.49
    • Unit Weight (lbs.): 14.13

      Environmental
    • Operating Temperature Range: 32 to 122F (0 to 50C)
    • Storage Temperature Range: -30°C to +60°C (-22°F to +140°F)
    • Relative Humidity: 5 to 95% non-condensing
    • Operating Elevation (ft.): 0-10,000
    • Operating Elevation (m): 0-3000m

      Communications
    • PowerAlert Software: LX Platform Interface: PowerAlert Device Manager15 (PADM15)
    • Communications Cable: USB B-to-USB A Configuration/Console Access cable
    • Network Monitoring Port: RJ45 Network port, RJ45 Config/Console Access port; 2x USB A ports supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules. USB B port (Configuration & Console Access)
    • SNMP Compatibility: SNMP V1, V2c, V3
    • Network Speed: 10/100 Mbps; 1Gbps
    • Communications Interface: Pre-installed network card; RS-232; USB
     
  • Item Includes:

    • 1x PDU3EVNR6G60A 16.2kW 3-Phase Monitored Per-Outlet PDU
    • 1x Built-in LX Platform interface
    • 1x Configuration cable
    • x18 Plug-lock insert sleeves
    • 1x Rack-mounting hardware
    • 1x Spare mounting buttons
    • 1x PDUMVROTATEBRKT mounting bracket accessory
    • 1x Owner’s manual
     
  • GTIN:

    0037332242242
     

PDU3EVNR6G60A - Required Accessories

    California Residents:
    WARNING:
    Cancer and Reproductive Harm - www.P65Warnings.ca.gov