Tripp Lite PDUB15 AC Power Distribution Unit Dual Source Hot Swap 12A 8 5-15R Horizontal
     
    Questions? Ask a Markertek Expert:
    800-522-2025 Email

    Tripp Lite PDUB15 AC Power Distribution Unit Dual Source Hot Swap 12A 8 5-15R Horizontal

    Manufacturer: Tripp Lite

    Item #: TRL-PDUB15   •   MFG #: PDUB15

     

    List Price:$311.06
    Our Price:$199.99

    free ship
     
     
    Availability:
    In Stock
    i
    Item is Available for immediate shipping from our warehouse.
     
     

      California Residents:
      8pt-triangleWARNING:
      Cancer and Reproductive Harm - www.P65Warnings.ca.gov

       
       
       

      Tripp Lite's PDUB15 Hot-swap PDU systems enable live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loads. Dual input power cables support PDU connection to separate Utility and UPS power sources. Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS. Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS. Set the switch to Utility to momentarily power connected equipment from the Utility line cord and bypass the UPS while the UPS system is removed and replaced with a fresh one. Once the new UPS is up and running with all data and electrical connections restored, set the switch back to the UPS setting to once again provide fully-conditioned UPS power to connected equipment.

       
      • Features

        • Single phase 15A 120V Hot-swap PDU
        • Enables live replacement of a standard UPS with zero downtime
        • 2U horizontal rackmount installation
        • Compatible with any 100-127V UPS with a 5-15P input plug
        • Manual transfer switch controls PDU input power source
        • Pair of 5-15P input cables connect to separate Utility and UPS inputs
        • 8 Built-in 5-15R outlets
        • 2-year limited warranty
        • 2U horizontal rackmount form factor compatible with 2 or 4 post racks
        • Supports space saving rear-post mounting in the same rack space as many Tripp Lite Rackmount UPS systems (select installations, see manual)
        • Pair of attached 5-15P PDU input cables connect to separate Utility and UPS power sources
        • 8 high quality 5-15R outlets support critical networking loads in both Utility and UPS operating modes
        • One additional 5-15R pass-through outlet supports UPS input power cord
        • Dual input power cables support PDU connection to separate Utility and UPS power sources
        • Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS
         
      • Specifications

        • Product Group: PDUS
        • Digital Load Meter: No
        • Redundant Power Cords: No
        • SNMP Compatible: No
        • TAA Compliant: No
        • Style: Rackmount
        • PDU Type: Hot-Swap
        • Output Capacity Details: 1.4kW (120V input), 1.5kW (127V input), 1.2kW (100V input); 15A maximum (Agency de-rated to 12A continuous)
        • Output Watt Capacity (Watts): 1440
        • Frequency Compatibility: 50 / 60 Hz
        • Output Receptacles: (8) 5-15R
        • Output Nominal Voltage: 100-127V nominal, single phase
        • Outlet Quantity / Type: 8 NEMA 5-15R outlets support critical connected loads; 1 designated pass-through 5-15R outlet supports UPS 5-15P input plug
        • Number of Outlets: 8
        • Outlet Type: NEMA 5-15R
        • PDU Input Voltage: 100; 120; 127
        • Maximum Input Amps: 12
        • PDU Plug Type: NEMA 5-15P
        • Input Cord Length Details: Utility input cable (10 ft / 3m) / UPS input cable (6 ft / 1.8m)
        • Input Phase: Single-Phase
        • Switches: Manual 2 position transfer switch offers fast switching between UPS and Utility operating modes in less than 6 milliseconds
        • Front Panel LEDs: Lighted indicators confirm UPS and Utility switch position and operating mode
        • Shipping Dimensions (hwd / in.): 9.25 x 20.23 x 6.1
        • Shipping Dimensions (hwd / cm): 23.5 x 51.4 x 15.5
        • Shipping Weight (lbs.): 11
        • Shipping Weight (kg): 5
        • Unit Dimensions (hwd / in.): 3.42 x 17.32 x 3.03
        • Unit Dimensions (hwd / cm): 8.7 x 44 x 7.7
        • Unit Weight (lbs.): 7.7
        • Unit Weight (kg): 3.5
        • Material of Construction: Steel
        • Form Factors Supported: 2U rackmount in 2 or 4 post racks
        • PDU Form Factor: Horizontal (1U, 2U, etc)
        • Relative Humidity: 0-95% non condensing
        • TAA Compliant Option: TAA Compliant Version Available - Order Tripp Lite PDUB15TAA
        • Certifications: Tested to UL60950 (USA), CSA (Canada)
        • Product Warranty Period (Worldwide): 2-year limited warranty
        • Selector Type: PDU'S
         
      • Item Includes

        • Hot-swap PDU System
        • 2U mounting brackets
        • User manual with warranty information
         
      • GTIN:

        0037332153876
         
       
       

      Add Accessories for your PDUB15:

       
       
       