    PDUMNH16HVAT - Overview

    The PDUMNH16HVAT 3.7kW Single-Phase 230V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and has an IEC309 16A Blue outlet for connecting a single device or a 0U 230V vertical PDU with IEC309 16A Blue plug. Dual 10-foot input cords with IEC309 16A Blue plugs connect to separate primary and secondary single-phase power sources, including out-of-phase sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds if the primary source fails or becomes unstable to ensure connected equipment remains powered.

    Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). Tiered access privileges allow both an administrator and a guest to log in. Automated alerts help prevent overloads, power loss and downtime. Digital display with LEDs indicates power availability, voltage, input status for both power sources, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module (sold separately).

    • Features:

      • Primary and Secondary Inputs for Power Redundancy
      • Offers remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
      • IEC309 16A Blue (2P+E) inputs with 10 ft. cords connect to separate primary and secondary single-phase power sources
      • Fault-tolerant, hot-swappable UPS protection when used with single UPS; fully redundant UPS protection when each cord is connected to a separate UPS Built-In IEC309 16A Blue Outlet
      • Powers a single device or indirectly powers equipment through a 0U 230V PDU with IEC309 16A Blue input (sold separately) Automatic Transfer Switching
      • Dynamic solid-state (TRIAC) automatic transfer switching
      • Switches to secondary power source if primary source fails or becomes unstable
      • 1–5 ms transfer time ensures uninterrupted operation of connected equipment
      • Built-in processor monitors power sources and prevents switching if secondary source is unavailable or of lower quality than primary source Multifunction Digital Display with LEDs
      • Reports input status for primary and secondary power sources, power availability, line voltage, frequency, amps, kilowatts and power factor Advanced Network Monitoring
      • Built-in Ethernet network interface allows full remote access for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP
      • Real-time load/current data with billing-grade accuracy (+/- 1 percent)
      • Tiered access privileges allow both an administrator and guest to log in
      • Optional ENVIROSENSE module (sold separately) monitors temperature and humidity Broad Communications Compatibility
      • Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP and NTP
      • 10/100 Mbps auto-sensing for communication with 10/100 Base-T networks Mounts Horizontally in 1U of Rack Space
      • Compatible with EIA-standard 19 in. 4-post racks and rack enclosures
      • Optional PDU4PKIT rail kit (sold separately) adds rear mounting support
       
    • Specifications:

      • PDU Type: Monitored; Auto-Transfer Switch
      • Output Capacity Details: 3.8kW (240V); 3.7kW (230V); 3.5kW (220V); 3.3kW (208V); 3.2kW (200V); 16A maximum
      • Frequency Compatibility: 50 / 60 Hz
      • Output Receptacles: (1) IEC309 16A BLUE (2P+E)
      • Output Nominal Voltage: 240, 230, 220, 208, 200
      • PDU Input Voltage: 200; 208; 220; 230; 240
      • Recommended Electrical Service: 16A 230V
      • Maximum Input Amps: 16
      • PDU Plug Type: IEC-309 16A BLUE (2P+E)
      • Input Cord Details: Set of two input cables for separate PRIMARY and SECONDARY input connections
      • Input Cord Length (ft.): 10
      • Input Cord Length (m): 3
      • Input Phase: Single-Phase
      • Front Panel LCD Display: Digital display reports input current in amps (Source A, Source B), output kilowatts (total), input voltage (Source A, Source B), input frequency (Source A, Source B) and output power factor
      • Front Panel LEDs: Front panel LEDs confirm amp (A) / kilowatt (kW) / voltage (V) / frequency (Hz) and power factor (PF) reporting information; Additional set of LEDs indicate Source A and Source B inputs for preferred, available and in-use status
      • Switches: ENTER and MODE switches toggle the digital display to display all reported information
      • Minimum Required Rack Depth (inches): 17.5
      • Shipping Dimensions (hwd / in.): 7.48 x 21.65 x 20.67
      • Shipping Weight (lbs.): 17.36
      • Unit Dimensions (hwd / in.): 1.72 x 16.93 x 14
      • Unit Weight (lbs.): 17.36
      • Material of Construction: Metal
      • Form Factors Supported: 1U rackmount
      • PDU Form Factor: Horizontal (1U, 2U, etc)
      • Operating Temperature Range: 32 to 122°F
      • Storage Temperature Range: 5 to 140°F
      • Relative Humidity: 5 to 95% (non-condensing)
      • Operating Elevation (ft.): 0-10,000
      • Certifications: Tested to CE (IEC60950-1+A1,A2; Class A)
      • Product Warranty Period (Worldwide): 2-year limited warranty
       