SU3000RTXL3U - Overview

Tripp Lite SU3000RTXL3U 3000VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 3U rackmount form factor with an installed depth of 26 inches. Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible) external battery packs. Full time sine wave 110 or 120V output with +/-2% voltage regulation. Online, double-conversion Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 150V. Highly efficient operation in optional economy mode saves BTU heat output and energy costs. NEMA L5-30P input plug. NEMA 5-15, NEMA 5-15/20R and NEMA L5-30R output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous communications via USB port, DB9 serial port and SNMPWEBCARD slot. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two-bank PDU switching supports load shedding and remote reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs. LED display panel easily rotates for viewing in rackmount or tower configurations. Dataline surge suppression for dialup, DSL or network Ethernet connection. Utility power and voltage regulation LEDs. Fault-tolerant auto-bypass mode.$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only).

What does Uninterruptible Power Supply (UPS) mean?
An uninterruptible power supply (UPS) provides nearly instantaneous power when the main utility power source fails, allowing either time for power to return or for the user to shut down the system or equipment normally by closing running computer system applications and using the operating system to shut down the system. The user has between five and 15 minutes to shut down a system normally or bring an auxiliary power source online to restore the power supply. In addition, most UPS systems also work to address power source electrical surges, sag voltage, voltage spikes, frequency instability, noise interference or harmonic distortion from the ideal sinusoidal wave form. If you're concerned about power failures, especially if you've lost work on your computer due to power outages in the past, you should buy a UPS. A UPS combines a surge suppressor with a big battery, and has special circuitry that detects a power failure and quickly switches over to run your equipment on its battery. The sole purpose of a UPS is to give you a few minutes at the start of a power failure to do two things:
-Save your work, and
-Shut down your computer.
Please Note: A UPS is not designed to let you continue to use your computer for hours and hours until the power comes back on. If properly chosen, a UPS will give you 5 to 10 minutes (possibly more) to save and do an orderly shutdown.

  • Features:

    • Includes 4 post rackmount installation accessories, Installation Form Factors Supported with Optional Accessories 2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND)
    • Supports extended runtime with optional external battery packs
    • Undervoltage Correction Maintains output during undervoltages to 160V AC
    • Severe Undervoltage Correction At load levels less than 70%, UPS maintains output during undervoltages to 130V AC
    • Switches 2 switches control off/on power status and alarm-cancel/self-test operation
    • Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch
    • Audible Alarm Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
    • LED Indicators 14 LEDs indicate line power, online mode, bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats
    • UPS AC Suppression Response Time Instantaneous.
    • Overvoltage Correction Maintains output during overvoltages to 275
     
  • Specifications:

    • Output Capacity Details: Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds
    • Output Volt Amp Capacity (VA): 3000
    • Output kVA Capacity (kVA): 3
    • Output Watt Capacity (Watts): 2400
    • Output kW Capacity (kW): 2.4
    • Power Factor: 0.8
    • Crest Factor: 0.125694444444444
    • Nominal Output Voltage(s) Supported: 200V; 208V; 220V; 240V
    • Nominal Voltage Details: 208V default
    • Frequency Compatibility: 50 / 60 Hz
    • Frequency Compatibility Details: Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start
    • Output Voltage Regulation (Line): +/- 2%
    • Output Voltage Regulation (Battery): +/- 2%
    • Output Receptacles: (6) 6-15/20R; (2) L6-20R
    • Load Management Receptacles: Two switchable 6-15/20R load banks (bank 1 - two outlets, bank 2 - four outlets)
    • Output AC Waveform (AC): Pure Sine wave
    • Output AC Waveform (Battery): Pure Sine wave
    • Rated input current (Max Load): 14.9A (200V), 14.3A (208V), 13.1A (220V), 12.1A (240V)
    • Nominal Input Voltage(s) Supported: 200V AC; 208V AC; 220V AC; 240V AC
    • UPS Input Connection Type: L6-20P
    • Input Circuit Breakers: 25A double pole
    • UPS Input Cord Length: 10'
    • Recommended Electrical Service: 20A
    • Input Phase: Single-Phase
    • Full Load Runtime: 5 min. (2400w)
    • Half Load Runtime: 14 min. (1200w)
    • DC System Voltage (VDC): 72
    • Battery Recharge Rate (Included Batteries): Less than 6 hours from 10% to 80% (typical, full load discharge)
    • Internal UPS Replacement Battery Cartridge: RBC96-3U
    • Battery Access: Front panel battery access door
    • Battery Replacement Description: Hot-swappable, user replaceable batteries
    • Voltage Regulation Description: Online, double-conversion power conditioning
    • UPS AC Suppression Joule Rating: 2670
    • UPS Dataline Suppression: 1 lfnea TEL/DSL o Ethernet
    • UPS Power Module Dimensions: 5.2" x 17.3" x 19.8"
    • Rack Height: 3U
    • UPS Power Module Weight: 74.9 lbs
    • UPS Shipping Dimensions: 13.3" x 23.8" x 25.7"