SU6000RT4UHVHW - Overview

Featuring true on-line operation with pure sine wave output, zero transfer time to battery and complete UPS replacement capability with no downtime, the SU6000RT4UHVHW provides the highest level of protection available for mission-critical equipment from power outages, voltage fluctuations and transient surges. It converts incoming AC power to DC, and re-converts it back to filtered AC output with a pure sine wave, isolating connected components from all power problems in high-voltage environments. The SU6000RT4UHVHW has a 6kVA/5400W capacity and hardwire output.With its detachable PDU with bypass switch, the SU6000RT4UHVHW is easily hot-swappable by a user of any skill set—no need for lengthy and expensive service calls, and no downtime if a repair or battery replacement is needed. In bypass mode, the PDU passes power to equipment without the use of the power and battery modules, allowing them to be removed while keeping your application in operation. UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The SU6000RT4UHVHW’s runtime can be expanded with optional external battery packs.The SU6000RT4UHVHW features a highly efficient (96%) economy mode setting that can significantly reduce a facility's energy costs by minimizing heat output, reducing cooling requirements and consuming less electricity.An LCD display with LED indicators enables IT personnel to operating modes and conditions. The LCD/LED panel rotates for viewing in horizontal rack or vertical tower installations and includes an audible alarm that signals various conditions.The SU6000RT4UHVHW features a USB port and a DB9 port that, when used with Tripp Lite's included PowerAlert software, provide comprehensive network power monitoring and control. An optional SNMPWEBCARD accessory can enable the UPS to operate as an IP managed device.The unit requires only 4U of rack space in a standard rack enclosure and can be installed in a 2-post rack using the 2POSTRMKITHD accessory, or in a tower configuration with the 2-9USTAND accessory.The SU6000RT4UHVHW comes with $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only) for connected equipment and a 2-year warranty.


What does Uninterruptible Power Supply (UPS) mean?
An uninterruptible power supply (UPS) provides nearly instantaneous power when the main utility power source fails, allowing either time for power to return or for the user to shut down the system or equipment normally by closing running computer system applications and using the operating system to shut down the system. The user has between five and 15 minutes to shut down a system normally or bring an auxiliary power source online to restore the power supply. In addition, most UPS systems also work to address power source electrical surges, sag voltage, voltage spikes, frequency instability, noise interference or harmonic distortion from the ideal sinusoidal wave form. If you're concerned about power failures, especially if you've lost work on your computer due to power outages in the past, you should buy a UPS. A UPS combines a surge suppressor with a big battery, and has special circuitry that detects a power failure and quickly switches over to run your equipment on its battery. The sole purpose of a UPS is to give you a few minutes at the start of a power failure to do two things:
-Save your work, and
-Shut down your computer.
Please Note: A UPS is not designed to let you continue to use your computer for hours and hours until the power comes back on. If properly chosen, a UPS will give you 5 to 10 minutes (possibly more) to save and do an orderly shutdown.

  • Specifications:

    • Output Capacity Details Output capacity de-rates to 4992 watts when used at 208V nominal; Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared
    • Output Volt Amp Capacity (VA) 6000
    • Output kVA Capacity (kVA) 6
    • Output Watt Capacity (Watts) 5400
    • Output kW Capacity (kW) 5.4
    • Power Factor 0.9
    • Crest Factor 0.125694444444444
    • Nominal Output Voltage(s) Supported 120V; 208V; 240V
    • Nominal Voltage Details This configuration requires the Power Module be set to 208 or 240V output voltage; included step-down transformer supports 120V output (when the voltage-selection switch on the transformer module is set to match the 208 or 240V power module setting)
    • Frequency Compatibility 60 Hz
    • Frequency Compatibility Details Output frequency regulation +/-0.05Hz (free running)
    • Output Voltage Regulation (Line Mode) +/- 2%
    • Output Voltage Regulation (Economy Line Mode) +/- 10%
    • Output Voltage Regulation (Battery Mode) +/- 2%
    • Output Receptacles (4) 5-15R; (8) 5-15/20R; (2) L6-20R; (2) L6-30R
    • Output Receptacle Details Output receptacles and input line cord are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement
    • Output Circuit Breakers High voltage 20A breaker protects L6-20R outlets, L6-30R outlets are unbreakered; Low voltage 20A breakers protect 4 5-15/20R outlets each; Low voltage 15A breakers protect 2 5-15/20R outlets each
    • Output AC Waveform (AC Mode) Pure Sine wave
    • Output AC Waveform (Battery Mode) Pure Sine wave
    • Rated input current (Maximum Load) 31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V)
    • Nominal Input Voltage(s) Supported 208V AC; 240V AC
    • Nominal Input Voltage Description Factory configured to 208V
    • UPS Input Connection Type L6-30P
    • UPS Input Cord Length (ft.) 10
    • UPS Input Cord Length (m) 3
    • Primary Form Factor Rackmount
    • UPS Power Module Dimensions (hwd, in.) 6.85 x 17.5 x 20.7
    • UPS Power Module Dimensions (hwd, cm) 17.4 x 44.5 x 52.6
    • Installed Whole System Maximum Rack Depth (in.) 21.8
    • Installed Whole System Maximum Rack Depth (cm) 55.4
    • Rack Height (U Spaces) 6
    • UPS Power Module Weight (lbs.) 116.2
    • UPS Power Module Weight (kg) 52.8
    • Stepdown Transformer Dimensions (hwd / in.) 3.5 x 17.5 x 21.8
    • Stepdown Transformer Dimensions (hwd / cm) 8.8 x 44.5 x 55.4
    • Stepdown Transformer Weight (lbs.) 72.6
    • Stepdown Transformer Weight (kg) 33
    • UPS Shipping Dimensions (hwd / in.) 22.5 x 25 x 30
    • UPS Shipping Dimensions (hwd / cm) 57.2 x 63.5 x 76.2
    • Shipping Weight (lbs.) 293
     
  • GTIN:

    0037332157089
     