Tripp Lite SU8000RT3UN50 8000VA 7200W UPS Smart Online Rackmount 8kVA PDU 200V-240V 6URM

ITEM #: TRL-SU8RT3UN50 MFG #: SU8000RT3UN50

Primary Image
  • Product Image Thumbnail 1 of 2
  • Product Image Thumbnail 2 of 2

This item is no longer available.
Ask a Markertek Expert if you need assistance finding an appropriate substitute.

(800) 522-2025Email

Items similar to the TRL-SU8RT3UN50

SU8000RT3UN50 - Overview

Tripp Lite SU8000RT3UN50 8000VA / 8kVA / 7200 watt online, double-conversion UPS system offers complete power protection for critical network applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking applications. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial applications. Cold-start operation supported. Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.


What does Uninterruptible Power Supply (UPS) mean?
An uninterruptible power supply (UPS) provides nearly instantaneous power when the main utility power source fails, allowing either time for power to return or for the user to shut down the system or equipment normally by closing running computer system applications and using the operating system to shut down the system. The user has between five and 15 minutes to shut down a system normally or bring an auxiliary power source online to restore the power supply. In addition, most UPS systems also work to address power source electrical surges, sag voltage, voltage spikes, frequency instability, noise interference or harmonic distortion from the ideal sinusoidal wave form. If you're concerned about power failures, especially if you've lost work on your computer due to power outages in the past, you should buy a UPS. A UPS combines a surge suppressor with a big battery, and has special circuitry that detects a power failure and quickly switches over to run your equipment on its battery. The sole purpose of a UPS is to give you a few minutes at the start of a power failure to do two things:
-Save your work, and
-Shut down your computer.
Please Note: A UPS is not designed to let you continue to use your computer for hours and hours until the power comes back on. If properly chosen, a UPS will give you 5 to 10 minutes (possibly more) to save and do an orderly shutdown.

  • Features:

    • Automatic inverter bypass; Manual bypass switch; Detachable hot-swap PDU; Hot swappable UPS power module; Hot swappable batteries
    • Green Energy-Saving High efficiency economy mode operation; Schedulable daily hours of economy mode operation
    • UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
    • UPS Certification Details IEC 61000-4-5 1995 B Surge Immunity
    • Product Warranty Period (Worldwide) 2-year limited warranty
    • Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance
     
  • Specifications:

    • Output Capacity Details Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less
    • Output Volt Amp Capacity (VA) 8000
    • Output kVA Capacity (kVA) 8
    • Output Watt Capacity (Watts) 7200
    • Output kW Capacity (kW) 7.2
    • Power Factor 0.9
    • Crest Factor 0.125694444444444
    • Nominal Output Voltage(s) Supported 120V; 208V
    • Nominal Voltage Details 7200 watts total output supported; 5000 watts maximum 120V output; Add 1 additional SU5000XFMRT2U transformer for full load 120V operation; This configuration requires the Power Module be set to 208V output voltage; included step-down transformer supports 120V output
    • Frequency Compatibility 60 Hz
    • Frequency Compatibility Details Output frequency regulation +/- 0.05Hz (free running)
    • Output Voltage Regulation (Line) +/- 2%
    • Output Voltage Regulation (Economy Line) +/- 10%
    • Output Voltage Regulation (Battery) +/- 2%
    • Output Receptacles (12) 5-15/20R; (4) L6-20R; (2) L6-30R
    • Output Circuit Breakers 20A double-pole (x2) protects 2 L6-20R outlets each, 30A double-pole (x2) protects 1 L6-30R outlets each, 20A single-pole (x4) protect 3 5-15/20R outlets each
    • Output AC Waveform (AC) Pure Sine wave
    • Output AC Waveform (Battery) Pure Sine wave
    • Rated input current (Max Load) 44.2A (208V)
    • Nominal Input Voltage(s) Supported 208V AC
    • UPS Input Connection Type Hubbell CS8265; Hardwire
    • UPS Input Connection Description 3 wire single phase input (L1, L2, G)
    • UPS Input Cord Length 10'
    • UPS Power Module Dimensions 5.14" x 17.5" x 25.82"
    • Installed Whole System Maximum Rack Depth 32.5"
    • Rack Height 8U
    • UPS Power Module Weight 43 lbs
    • UPS Dimensions Details Installed Whole System Maximum Rack Depth refers to the installed depth with the included Bypass PDU attached to the UPS power module
    • Stepdown Transformer Dimensions 3.5" x 17.5" x 20.8"
    • Stepdown Transformer Weight 57 lbs
    • Included Battery Pack Dimensions 5.25" x 17.5" x 25"
    • Included Battery Pack Weight 158.7 lbs
    • UPS Shipping Dimensions 49.25" x 23" x 31.5"
    • Shipping Weight 402.2 lbs
    • Cooling Method Fan
    • UPS Housing Material Steel
    • Operating Temperature Range +32 to +104 degrees
    • Storage Temperature Range +5 to +122 degrees
    • Relative Humidity 0 to 95%, non-condensing
    • AC Mode BTU / Hr. (Full Load) 2732
    • AC Economy Mode BTU / Hr. (Full Load) 1020
    • Battery Mode BTU / Hr. (Full Load) NULL
    • AC Mode Efficiency Rating (100% Load) 0.91
    • AC Economy Mode Efficiency Rating (100% Load) 0.96
    • Operating Elevation (ft.) 0-3000m (0 to 10,000 ft.)
    • Audible Noise 60 dBA at front side 1 meter
    • Operating Elevation (m) 0-3000 m
    • Communications Interface USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
    • Network Monitoring Port Description Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports
    • WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
    • Transfer Time No transfer time (0 ms.) in online, double-conversion mode
    • Transfer Time (Economy Mode) 8 ms. typical power failure response in optional economy mode
    • Low Voltage Transfer to Battery Power (Setpoint) 100V
    • High Voltage Transfer to Battery Power (Setpoint) 300V
     
  • Item Includes:

    • PowerAlert Software Included
    • Communications Cable,USB, DB9 serial and EPO cables included
     
  • GTIN:

    0037332142511
     

SU8000RT3UN50 - Required Accessories

    California Residents:
    WARNING:
    Cancer and Reproductive Harm - www.P65Warnings.ca.gov