The NTI 600-000-394 battery-operated Class 2 Sound Calibrator is classified for the calibration of class 2 measurement microphones, sound level meters and other acoustic measurement equipment. This microphone calibrator delivers 114 dB at a frequency of 1 kHz..

The Sound Calibrator features a stable sound pressure independent of the battery condition. It guarantees a reliable output and will turn off automatically to preserve battery.

Applications for Sound Level Measurement
Ensure accurate measurements
Adapt the measurement microphone to the local environmental conditions, such as temperature, humidity, and air pressure
Verify the stability of the sound level meter

Please Note! 1/4" and 1/2" Class 2 Measurement Mics refer to the diameter of the mic capsule ! Not the actual mic size of the mic itself. The mic capsule docks with this calibrator in order for the unit to do its thing!

  • Features:

    • Output level: 114 dB
    • Output frequency: 1 kHz
    • Compliant with standards IEC 60942-1:2017 and ANSI S1.40-2006 (R2016)
    • Battery-operated
    • For 1/2" and 1/4" measurement microphones (1/4" adapter included)
     
  • Specifications:

    • Sound Pressure Level: 114.0 dB ±0.25 dB SPL reference to 20µPa
    • Stability After Pressing On: ±0.25 dB after 5 seconds
    • Short-term Level Stability: < ±0.2 dB
    • Maximum Deviation: < ±0.6 dB
    • Frequency: 1 kHz ±5 %
    • Harmonic Distortion: < 1 %
    • Calibration Reference Condition: 101.3 kPa, 23 °C und 50 % RH
    • Static Pressure Range: 65 to 108 kPa; pressure coefficient < 0.004 dB/kPa
    • Temperature Range: 0 to +40 °C (32 to 104 °F)
    • Relative Humidity Range: 25 to 90 % RH
    • Storage Temperature: -20 to +60 °C
    • Humidity: 0 to 90 % RH (non condensing)
    • Dimensions L x W x H: 2.9 x 2.1 x 1.4"
    • Weight: 85 g (0.19 lb)
    • Battery: 2x AAA (LR03), Battery Voltage Operating Range 1.75 to 3.6 V
    • Standards: IEC 60942:2017, class 2, ANSI S1.40-2006 (R2016), EMC directive 2004/108/EC, IEC 61326- 1:2005, EN 61000-4-2:2009 electrostatic discharge immunity, EN 61000-4-3:2010 electromagnetic field immunity, EN 61000-6-3:2011 electromagnetic field immunity
     
  • Item Includes: