Tripp Lite SU60KX SmartOnline 60kVA Modular 3-Phase UPS System On-line Double-Conversion International UPS

ITEM #: TRL-SU60KX MFG #: SU60KX

Primary Image
  • Product Image Thumbnail 1 of 2
  • Product Image Thumbnail 2 of 2

This item is no longer available.
Ask a Markertek Expert if you need assistance finding an appropriate substitute.

(800) 522-2025Email

Items similar to the TRL-SU60KX

SU60KX - Overview

Tripp Lite's SU60KX (60kVA) SmartOnline Modular 3-Phase Intelligent, True On-Line UPS System provides 100% system availability with N+1 modular architecture and 1+1 parallel capability. In N+1 configuration, the SU60KX provides three self-contained, redundant 20kVA power modules that can be hot-swapped (load remaining powered) if maintenance is required. In 1+1 configuration , two SU60KX models connected in parallel can provide fail-safe redundancy (two 60kVA models supporting a 60kVA load) or increased capacity (two 60kVA models supporting a 120kVA load). Large capacity 60,000VA/48,000W UPS continually converts incoming AC power into filtered DC power, and then resynthesizes it back into AC power with a pure sine wave. Perfectly regulated, continuous sine wave output with zero transfer time assures compatibility with all equipment types. High input power factor, advanced IGBT inverter technology and Digital Signal Processor (DSP) technology produce less than 3% input total harmonic distortion (THDi). With low THDi, generators run cooler and last longer, allowing managers to save installation costs by installing a generator with a capacity equal to the equipment load (1:1 ratio). Extremely efficient operation (up to 97%) saves money by lowering electricity consumption. Hardwire input and output connections support a variety of permanent or PDU-style power connections. Frequency is 50 or 60 Hz (auto-selectable). SU60KX power modules are housed in a single small-footprint tower compartment. Battery modules (Models BP480V26B and BP480V40C) are housed in a separate stand-alone hardwired external battery compartment (required for UPS operation/backup battery support; order separately). Battery runtime can be extended with additional stand-alone hardwired external battery modules. A manual bypass breaker and an automatic bypass function ensure 100% availability of connected equipment by safely passing through AC power if the UPS requires maintenance.

  • Features:

    • N+1 configuration: If maintenance is required, three self-contained, redundant 20kVA power modules can be hot-swapped with the load remaining powered
    • 1+1 configuration: Two SU60KX can be connected in parallel to provide either fail-safe redundancy or increased capacity
    • High input power factor, advanced IGBT inverter technology and Digital Signal Processor (DSP) technology produce low input total harmonic distortion (THDi)
    • Low THDi (less than 3%) reduces installation costs by allowing 1:1 generator sizing
    • Extremely efficient operation (up to 97%) saves money by reducing electricity consumption
    • True on-line, double-conversion UPS with IGBT technology provides pure sine wave AC output at all times
    • Maintains continuous operation with zero transfer time through blackouts, voltage fluctuations and surges
    • Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems
    • 60,000VA/48,000W power capacity with 3-phase, hardwire input/output connections
    • Wide input voltage correction range: 173-300V/276-477V AC
    • Precision +/-1% output voltage regulation
    • Battery modules (Models BP480V26B and BP480V40C) are housed in a separate, stand-alone hardwired external battery compartment (required for UPS operation/backup battery support; order separately)
    • Battery runtime can be extended with additional stand-alone hardwired external battery modules (Models BP480V26B and BP480V40C; order separately)
    • Front panel combination LCD/LED display includes a real-time event log screen with up to 500 events listed
    • Dynamic battery management screen optimizes battery function to lengthen service life and allow cold restart of the UPS
    • Built-in RS-232 communication port works with included PowerAlert Software to provide shutdown commands and reporting on a single server
    • Accessory slot accepts an optional internal SNMP card (Model SNMPWEBCARD) for remote shutdowns, reboots and more
    • Emergency Power Off button turns UPS output OFF and disables Bypass output
    • Built-in Emergency Power Off (EPO) dry-contact interface supports remote emergency shutdown in large facilities
     
  • Specifications:

    • Output Volt Amp Capacity (VA): 60000
    • Output Watt Capacity (Watts): 48000
    • Power Factor: 0.8
    • Crest Factor: 0.125694444444444
    • Nominal Output Voltage(s) Supported: 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
    • Frequency Compatibility: 50 / 60 Hz
    • Output Voltage Regulation (Line Mode): +/-1%
    • Output Voltage Regulation (Battery Mode): +/-1%
    • Output Receptacles: Hardwire
    • Output AC Waveform (AC Mode): Sine wave
    • Output AC Waveform (Battery Mode): Pure Sine wave
    • Rated input current (Maximum Load): 73A/76A/79A
    • Nominal Input Voltage(s) Supported: 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
    • Nominal Input Voltage Description: 3-Phase Wye, 4 wire (L1, L2, L3, N, G)
    • UPS Input Connection Type: Hardwire
    • Input Phase: 3-Phase
    • Expandable Battery Runtime: Battery set sold separate
    • External Battery Pack Compatibility: BP480V200; BP480V26B; BP480V300; BP480V400; BP480V40C; BP480V500
    • DC System Voltage (VDC): +/- 240VDC
    • Overvoltage Correction: Maintains continuous operation without using battery power during overvoltages to 276-477 (3-phase, 4-wire, wye), reducing output within 1% of nominal
    • Undervoltage Correction: Maintains continuous operation without using battery power during brownout/undervoltage conditions to 173-300 (3-phase, 4-wire, wye)
    • Alarm Cancel Operation: Power-fail alarm can be silenced using alarm-cancel switch
    • LED Indicators: 4-LED Display: Displays normal AC input, on battery power, bypass input and fault conditions
    • EMI / RFI AC Noise Suppression: Yes
    • AC Suppression Joule Rating: 5950
    • AC Suppression Response Time: Instantaneous
    • Primary Form Factor: Tower
    • UPS Power Module Dimensions (hwd, in.): 46 x 20.5 x 33.7
    • UPS Power Module Weight (lbs.): 463
    • UPS Shipping Dimensions (hwd / in.): 55 x 28.5 x 42.5
    • Shipping Weight (lbs.): 613
    • Cooling Method: Fans
    • UPS Housing Material: Steel
    • Operating Temperature Range: +32 to +104° F
    • Storage Temperature Range: +5 to +122° F
    • Relative Humidity: 0 to 95%, non-condensing
    • AC Mode BTU / Hr. (Full Load): 10509
    • Battery Mode BTU / Hr. (Full Load): 10463
    • Communications Interface: DB9 Serial; Slot for SNMP/Web interface
    • Network Management Cards: SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
    • PowerAlert Software: For local monitoring via the UPS's built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
    • Communications Cable: DB9 cabling included
    • Product Warranty Period (International): 2-year limited warranty
     
  • Item Includes:

    • SU60KX UPS System
    • PowerAlert Software
    • Instruction manual
    • Warranty information
     
  • Warranty:

    • 2 Year
     
  • GTIN:

    0037332141415
     

SU60KX - Required Accessories

    California Residents:
    WARNING:
    Cancer and Reproductive Harm - www.P65Warnings.ca.gov