Tripp Lite PDUMNH32HV PDU Monitored 230V 7.3kW 32A 12 C13; 4 C19 IEC-309 Horizontal 2U

ITEM #: TRL-PDUMNH32HV MFG #: PDUMNH32HV

Primary Image
  • Product Image Thumbnail 1 of 5
  • Product Image Thumbnail 2 of 5
  • Product Image Thumbnail 3 of 5
  • Product Image Thumbnail 4 of 5
  • Product Image Thumbnail 5 of 5
Free Shipping with $49 Minimum Order

List Price:

$1,050.20

Our Price:

$734.00

Availability: Typically Ships in 3-10 Business Days
iAvailability Description Popup


    PDUMNH32HV - Overview

    Tripp Lite single phase Monitored PDU / Power Distribution Unit offers real-time remote monitoring of voltage, frequency and load levels via built-in network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. PDU lighted digital display enables visual monitoring of PDU output current to prevent circuit overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.

    Tripp Lite PDUMNH32HV single phase Monitored PDU / Power Distribution Unit offers real-time remote monitoring of voltage, frequency and load levels via built-in network connection. Built-in LX Platform network management interface. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. PDU lighted digital display enables visual monitoring of PDU output current to prevent circuit overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.

    Management Interface
    The management interface for this PDU model is transitioning to a new technology platform. The new interface can be distinguished by a USB-A port (for EnviroSense2 modules) in place of the round ENVIROSENSE port. For managing the units containing the round port, Tripp Lite recommends using the PowerAlert Console Launcher rather than a web browser. This application enables local access of the PDU using a self-contained, compatible Java Runtime Environment version. The Console Launcher can be downloaded for free; click the above link or go to the Management Solutions / Utilities page. Units with the new interface work will with most current web browsers.

    • Features:

      • 32A 7.3kW single phase 230V Monitored Power Distribution Unit / PDU
      • Attached Blue IEC-309 32A (2P+E) input plug with 3.65m line cord
      • 2U horizontal rackmount format
      • 16 outlets (12 C13, 4 C19)
      • Lighted display with select button reports output power consumption in amps in 3 segments (bank 1, bank 2 and total)
       
    • Specifications:

      • Input
      • PDU Input Voltage: 230
      • Recommended Electrical Service: 32A 230V
      • Maximum Input Amps: 32
      • PDU Plug Type: IEC-309 32A BLUE (2P+E)
      • Input Phase: Single-Phase
      • Input Cord Length (ft.): 12

        Output
      • Output Capacity Details: 7.4kW (230V) / 32A total capacity / 16A max per breakered outlet bank; 16A max per C19 outlet; 10A max per C13 outlet
      • Frequency Compatibility: 50 / 60 Hz
      • Output Receptacles: (12) C13; (4) C19
      • Output Nominal Voltage: 230
      • Overload Protection: Two 20A circuit breakers protect 8 outlets each

        Physical
      • Form Factors Supported: 2U rackmount
      • Material of Construction: Metal
      • Minimum Required Rack Depth (inches): 16
      • PDU Form Factor: Horizontal (2U)
      • Shipping Dimensions (hwd / in.): 7.90 x 16.90 x 20.20
      • Shipping Weight (lbs.): 15.60
      • Unit Dimensions (hwd / in.): 3.5 x 17.5 x 12.5
      • Unit Weight (lbs.): 13.7

        Environmental
      • Storage Temperature Range: -30°C to +50°C (-22°F to +122°F)
      • Relative Humidity: Up to 95% non-condensing

        Communications
      • SNMP Compatibility: Pre-installed LX platform interface provides remote monitoring via Java-free HTML5 web interface, telnet, SSH and SNMP management systems

        Special Features
      • High Availability PDU Features : Auto Probe Monitoring (included)

        Standards & Compliance
      • Certifications: Tested to CE (IEC 60950-1), EN Class A (Emissions), RoHS compliant, TAA Compliant
       
    • GTIN:

      0037332159229
       

    PDUMNH32HV - Required Accessories

      California Residents:
      WARNING: